Call 07942561367 85% Response Rate

Send Enquiry

our range

Fire Alarm

Leading Manufacturer of manual call point, addressable smoke detector, gst addressable fire alarm control panel, gst smoke detectors, optical beam smoke detector and sprinkler rosette plate from Coimbatore.

Manual Call Point

  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
  • Manual Call Point
Manual Call Point
Get Best Quote
Rs 350  / PiecePrice on Request

Minimum Order Quantity: 10 Piece

Product Brochure

Operation TypeBreak glass
System TypeFire and security
System CompatibilityConventional
Panel Capacity4 zone
Mounting TypeSurface mount
CommunicationGSM
Usage/ApplicationApartments
Contact TypeNO
Integrated DevicesSmoke
ApplicationWarehouse, Office, Bank
Power Supply230 V AC
ColorRed
Relay OutputsAlarm Relay
MaterialMS (Body)
Weight300gm
FeaturesIn case of fire break glass
Model Name/NumberSFU151106
Voltage12 V
Dimensions124 x 95 x 58 mm
BrandAses
ASES is one of the biggest manufacturer of Conventional Fire Alarm Systems & Accessories. We are also have an unique product called " DIGITAL ADDRESSABL

View Complete details

Yes! I am Interested Request a call back

Addressable Smoke Detector

  • Addressable Smoke Detector
  • Addressable Smoke Detector
  • Addressable Smoke Detector
  • Addressable Smoke Detector
  • Addressable Smoke Detector
Addressable Smoke Detector
Get Best Quote
Rs 1,550  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Model SeriesI-9402
TypeSingle loop system
System TypeConventional
Detector TypePhotoelectric
Operating Voltage24 volt
Body MaterialABS Plastic
Startup Time (sec)5 sec
Alarm IndicationLED
Loop ProtocolGST
Brand/CompanyGST
The addressable automatic fire alarm system shall consist of a main control panel, remote power supply panels, remote control panels, detection devices, manual stations, HVAC fan relay control modules, and magnetically-held fire door relay control modules that are wired in accordance with the schedule on the drawings and shall function as specified below. The system shall be capable of being expanded at any time. The system shall be capable of operating both addressable and non-addressable thermal and photoelectric detecting devices, manual stations, sprinkler supervisory switches and water-flow switches. Supervisory switches shall be set up for supervisory (trouble) causing only. The system shall function as follows when any smoke detector, heat detector, duct detector, manual pull station, or water flow switch operates: • Sound the required audible notification devices as shown on the drawings. o Activate the EVAC message. • Illuminate all visual notification devices as shown on the drawings. • Notify the fire department via the OSU central reporting station using Bosch B465 Universal dual path communicator. Contact Facilities Management, MEP Life Safety group for account number, phone numbers or any other required information for reporting and programming. • Display the device(s) and location of the device(s) in alarm and in trouble on the LCD display and interactive display system. • Conventional zones (monitor modules) are to display the area of protection. • Light an indicating lamp on the device initiating the alarm. • Shut down the HVAC system and operate dampers as shown on the drawings. • Close all magnetically-held fire doors as shown on the drawings. • Operate smoke removal systems, if required for that initiating device. • Activate emergency elevator operation, if required for that initiating device. • Activate natural gas shutoff (only if alarm exists in the area of natural gas). • Duct detector shall initiate a supervisory signal not a fire alarm. NOTE: There shall be no limit, other than the maximum system capacity, as to the number of addressable devices that may be in alarm simultaneously.

Additional Information:

  • Delivery Time: 1 day
  • Packaging Details: by parcel

View Complete details

Yes! I am Interested Request a call back

GST Addressable Fire Alarm Control Panel

  • GST Addressable Fire Alarm Control Panel
  • GST Addressable Fire Alarm Control Panel
  • GST Addressable Fire Alarm Control Panel
GST Addressable Fire Alarm Control Panel
Get Best Quote
Rs 28,800  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Panel TypeConventional
Usage/ApplicationIndustrial
Loop Capacity235 addresses
MaterialMild Steel (MS)
Display TypeLCD
BrandRavel
Number of Zone2
Number of Zones4
Number of Loops1
Check the circuit connected with the FACP. Measure the insulation resistance between loops and between loops and ground, which should be more than 20MΩ. Measure the load of detection loops, which should be more than 1kΩ. The resistance between cables of FIRE ALARM OUTPUT, SOUNDER CIRCUIT OUTPUT and F.P.E. OUTPUT should be equal to the end-of-line resistance.

Additional Information:

  • Item Code: 9013
  • Production Capacity: Good
  • Delivery Time: 1 dad
  • Packaging Details: immediate

View Complete details

Yes! I am Interested Request a call back

GST Smoke Detectors

  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
  • GST Smoke Detectors
GST Smoke Detectors
Get Best Quote
Rs 980  / PiecePrice on Request

Minimum Order Quantity: 5 Piece

Product Brochure

Model SeriesI-9102
System TypeStandalone
Operating Voltage24 V DC
Alarm IndicationLED
Loop ProtocolGST
Usage/ApplicationResidential Buildings
ColorWhite
Automation GradeAutomatic
Country of OriginMade in India
Alarm Sensor TypeIonization
Detector TypePhotoelectric

Feature
   ☆Ultraviolet sensor that detects the UV rays produced by a flame
   ☆Aesthetically pleasing Low profile design
   ☆Dust / corrosion / humidity resistant
   ☆Electronically addressed
   ☆Three sensitivity levels

Technical Specifications
   ☆Operating Voltage: 24VDC
   ☆Operating Current:
                      Standby Current: 2mA
                      Alarm Current: 2.5mA
   ☆Operating Environment:
                          Temperature: -10℃ ~+50℃
                          Relative Humidity: 95% non condensing
   ☆Dimensions: Diameter 103mm, Height 53.5mm



Additional Information:

  • Production Capacity: loop 24V (16V ~ 28V)
  • Delivery Time: immediatly
  • Packaging Details: by box

View Complete details

Yes! I am Interested Request a call back

Optical Beam Smoke Detector

  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
  • Optical Beam Smoke Detector
Optical Beam Smoke Detector
Get Best Quote
Rs 20,500  / PiecePrice on Request

Minimum Order Quantity: 5 Piece

Product Brochure

Coverage Range10 to 40 m
Range (meter)60m
Beam TypeReflective
Alarm IndicationLED With Sounder
System TypeConventional
Operating Voltage9.5V - 28V DC
Usage/ApplicationIndustrial
Mounting TypeCeiling
Relay OutputWithout Relay
Alignment MethodManual
Base TypeIsolator Base
Response Time10 to 20 sec
Alarm Sensor TypePhotoelectric
Product TypeOPTICAL BEAM DETECTOR
Colormilk white
Power SourceOperating distance range for RE-428FR reflector 5 m to 50 m
Automation GradeAutomatic
Operating Current20 mA
Power60 mA
Voltage9.5V - 28V DC
Sensor Sensitivity18%, 30%, 50%
Frequency< 0.3 mA
BrandRavel
Operating Temperature-25oC to 55oC
FeaturesRE-102 Conventional 2 IDC Fire Alarm Control Panel RE-104 Conventional 4 IDC Fire Alarm Control Pane
Storage Temperature-25oC to 60oC
Relative Humidityup to 95% at 40oC
CertificationLPCB
IP Rating (Protection Rating)IP 50
Dimension128 x 79 x 84 mm
Weight0.35 kg
ReferenceOperating distance range for RE-428HR reflector 5 m to 100 m
Country of OriginMade in India
Optical Beam detector working range 50 meter and 100 meter, Beam detector is LPCB certified with inbuilt laser light for easy pointing the prism location, easy to align, sensitivity threshold setting changeable along with remote indicator output option. Maintenance free, effective sensing beam detectors. Compared to point smoke detectors, beam detectors are sensitive to a medium smoke density value on a long path of the infrared radiation beam. Therefore they are especially suitable for application under high ceilings/roofs or in those places, where smoke can be diffused over a large area before detection.

Additional Information:

  • Delivery Time: 1 day
  • Packaging Details: parcel

View Complete details

Yes! I am Interested Request a call back

Sprinkler Rosette Plate

  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
  • Sprinkler Rosette Plate
Sprinkler Rosette Plate
Get Best Quote
Rs 70  / PiecePrice on Request

Minimum Order Quantity: 10 Piece

Product Brochure

UsageDoor Handle
MaterialMild Steel
ShapeRound
FinishMatt
Outer Diameter40 mm
ColorMilk white
BrandKSK
Mounting TypeCeiling Mounted
Size/Dimension1/2" 3/4"
Surface FinishingCoatin g
Country of OriginMade in India
Dimeter50 mm
Inner Hole Size10 mm
A smoke detector rosette plate, also known as an escutcheon plate, is a decorative cover that hides the gap between the sprinkler head and the ceiling or wall, providing a finished look. These plates are often made of steel or brass. They are used with both pendant and recessed sprinklers. 

Additional Information:

  • Delivery Time: Immediate
  • Packaging Details: By trasnport

View Complete details

Yes! I am Interested Request a call back

Fire Response Indicator

  • Fire Response Indicator
  • Fire Response Indicator
Fire Response Indicator
Get Best Quote
Rs 55  / PiecePrice on Request

Minimum Order Quantity: 10 Piece

Product Brochure

Operating Voltage24 volt
MaterialMild Steel
Alarm Sensor TypePhotoelectric
Operating Current24 volt
Usage/ApplicationIndustrial Premises
ColorWhite
BrandKsk
Automation GradeManual
Dimension50x60
WirelessYes

A response indicator is a visual aid, often a small LED light or device, that connects to a fire alarm detector to provide immediate notification of the source of an alarm signal, especially in areas where detectors are not easily seen or accessed. These indicators help quickly pinpoint the location of the triggering detector, facilitating faster response times and reducing the need to search for the source of the alarm. Here's a more detailed description:

Function:Response indicators are designed to illuminate when the connected fire detector is triggered, indicating the source of the alarm. 

Purpose:They are particularly useful for detectors located in difficult-to-reach areas like attics, under false ceilings or floors, or in enclosed spaces. 

Components:They typically consist of an indicator lamp unit with one or two LED lights. 

Benefits:

Quick Identification: They provide a fast visual indication of the alarm source, allowing for quicker response to the fire. 

Improved Safety: By pinpointing the alarm source, they help reduce the risk of false alarms and ensure that the proper response is taken. 

Reduced Search Time: They minimize the time spent searching for the triggering detector, especially in larger buildings or complex layouts. 

Types:Response indicators can be designed for various types of fire detectors, including smoke, heat, and flame detectors. 

Installation:They are typically installed near the connected detector, providing a clear and visible indication of the alarm status.

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES